Skip to content
New issue

Have a question about this project? Sign up for a free GitHub account to open an issue and contact its maintainers and the community.

By clicking “Sign up for GitHub”, you agree to our terms of service and privacy statement. We’ll occasionally send you account related emails.

Already on GitHub? Sign in to your account

[shelly] Some channels on Shelly Pro 3EM report NULL #16772

Open
hoinmic opened this issue May 18, 2024 · 3 comments
Open

[shelly] Some channels on Shelly Pro 3EM report NULL #16772

hoinmic opened this issue May 18, 2024 · 3 comments
Assignees
Labels
bug An unexpected problem or unintended behavior of an add-on

Comments

@hoinmic
Copy link

hoinmic commented May 18, 2024

The Shelly Pro 3EM device does not display all values, some channels display " NULL ". The debug functionality of the shelly addon shows the arrival of the corresponding data, but the channel are not updated.

Tested with the commits on the openhab-addons branch 4.2.0~M2-1

I have not yet discovered any errors in the shelly folder of the openhab-addons repository.

Does anyone have an idea what is wrong here?

Logs:

2024-05-18 22:29:00.050 [INFO ] [org.openhab.core.model.script.power ] - -----------------------
2024-05-18 22:29:00.050 [INFO ] [org.openhab.core.model.script.power ] - Current_Power_Meter1_Inverter: 0
2024-05-18 22:29:00.050 [INFO ] [org.openhab.core.model.script.power ] - Total_Energy_Meter1_Inverter: NULL
2024-05-18 22:29:00.050 [INFO ] [org.openhab.core.model.script.power ] - Total_Energy_Returned_Meter1_Inverter: 0
2024-05-18 22:29:00.057 [INFO ] [org.openhab.core.model.script.power ] - Reactive_Power_Meter1_Inverter: NULL
2024-05-18 22:29:00.058 [INFO ] [org.openhab.core.model.script.power ] - Voltage_Meter1_Inverter: 0
2024-05-18 22:29:00.058 [INFO ] [org.openhab.core.model.script.power ] - Current_Meter1_Inverter: 0.028
2024-05-18 22:29:00.058 [INFO ] [org.openhab.core.model.script.power ] - Power_Factor_Meter1_Inverter: 0
2024-05-18 22:29:00.058 [INFO ] [org.openhab.core.model.script.power ] - Last_Update_Meter1_Inverter: 2024-05-18T22:28:17.000+0200
2024-05-18 22:29:00.059 [INFO ] [org.openhab.core.model.script.power ] - Reset_Total_Meter1_Inverter: NULL
2024-05-18 22:29:00.059 [INFO ] [org.openhab.core.model.script.power ] - -----------------------
2024-05-18 22:29:00.059 [INFO ] [org.openhab.core.model.script.power ] - Current_Power_Meter2_Inverter: 0
2024-05-18 22:29:00.059 [INFO ] [org.openhab.core.model.script.power ] - Total_Energy_Meter2_Inverter: NULL
2024-05-18 22:29:00.059 [INFO ] [org.openhab.core.model.script.power ] - Total_Energy_Returned_Meter2_Inverter: 0
2024-05-18 22:29:00.060 [INFO ] [org.openhab.core.model.script.power ] - Reactive_Power_Meter2_Inverter: NULL
2024-05-18 22:29:00.060 [INFO ] [org.openhab.core.model.script.power ] - Voltage_Meter2_Inverter: 0
2024-05-18 22:29:00.060 [INFO ] [org.openhab.core.model.script.power ] - Current_Meter2_Inverter: 0.028
2024-05-18 22:29:00.060 [INFO ] [org.openhab.core.model.script.power ] - Power_Factor_Meter2_Inverter: 0
2024-05-18 22:29:00.060 [INFO ] [org.openhab.core.model.script.power ] - Last_Update_Meter2_Inverter: 2024-05-18T22:28:50.000+0200
2024-05-18 22:29:00.060 [INFO ] [org.openhab.core.model.script.power ] - Reset_Total_Meter2_Inverter: NULL
2024-05-18 22:29:00.061 [INFO ] [org.openhab.core.model.script.power ] - -----------------------
2024-05-18 22:29:00.061 [INFO ] [org.openhab.core.model.script.power ] - Current_Power_Meter3_Inverter: 0
2024-05-18 22:29:00.061 [INFO ] [org.openhab.core.model.script.power ] - Total_Energy_Meter3_Inverter: NULL
2024-05-18 22:29:00.061 [INFO ] [org.openhab.core.model.script.power ] - Total_Energy_Returned_Meter3_Inverter: 0.007
2024-05-18 22:29:00.061 [INFO ] [org.openhab.core.model.script.power ] - Reactive_Power_Meter3_Inverter: NULL
2024-05-18 22:29:00.061 [INFO ] [org.openhab.core.model.script.power ] - Voltage_Meter3_Inverter: 238.8
2024-05-18 22:29:00.062 [INFO ] [org.openhab.core.model.script.power ] - Current_Meter3_Inverter: 0.028
2024-05-18 22:29:00.062 [INFO ] [org.openhab.core.model.script.power ] - Power_Factor_Meter3_Inverter: 0
2024-05-18 22:29:00.062 [INFO ] [org.openhab.core.model.script.power ] - Last_Update_Meter3_Inverter: 2024-05-18T22:28:50.000+0200
2024-05-18 22:29:00.062 [INFO ] [org.openhab.core.model.script.power ] - Reset_Total_Meter3_Inverter: NULL
2024-05-18 22:29:00.062 [INFO ] [org.openhab.core.model.script.power ] - -----------------------
.....

Shelly-addon logs:

2024-05-18 22:29:04.073 [DEBUG] [g.shelly.internal.api2.Shelly2ApiRpc] - shellypro3em-pvinverter: NotifyStatus update received: {"src":"shellypro3em-34987a467758","dst":"shellypro3em-pvinverter","method":"NotifyStatus","params":{"ts":1.71606413072E9,"em:0":{"id":0,"a_current":0.028,"a_voltage":0.0,"a_act_power":0.0,"a_aprt_power":0.0,"a_pf":0.0,"b_current":0.027,"b_voltage":0.0,"b_act_power":0.0,"b_aprt_power":0.0,"b_pf":0.0,"c_current":0.027,"c_voltage":239.0,"c_act_power":0.0,"c_aprt_power":6.6,"c_pf":0.0,"total_current":0.082,"total_act_power":0.0,"total_aprt_power":6.561}}}
.....

Items file:

// Energy Meter1 Inverter
Number Current_Power_Meter1_Inverter {channel="shelly:shellypro3em:pvInverter:meter1#currentWatts"}
Number Total_Energy_Meter1_Inverter {channel="shelly:shellypro3em:pvInverter:meter1#totalKWH"}
Number Total_Energy_Returned_Meter1_Inverter {channel="shelly:shellypro3em:pvInverter:meter1#returnedKWH"}
Number Reactive_Power_Meter1_Inverter {channel="shelly:shellypro3em:pvInverter:meter1#reactiveWatts"}
Number Voltage_Meter1_Inverter {channel="shelly:shellypro3em:pvInverter:meter1#voltage"}
Number Current_Meter1_Inverter {channel="shelly:shellypro3em:pvInverter:meter1#current"}
Number Power_Factor_Meter1_Inverter {channel="shelly:shellypro3em:pvInverter:meter1#powerFactor"}
DateTime Last_Update_Meter1_Inverter {channel="shelly:shellypro3em:pvInverter:meter1#lastUpdate"}
Switch Reset_Total_Meter1_Inverter {channel="shelly:shellypro3em:pvInverter:meter1#resetTotals"}
.....

Rules file:

  logInfo(logName, "-----------------------")
  logInfo(logName, "Current_Power_Meter1_Inverter: " + Current_Power_Meter1_Inverter.state)
  logInfo(logName, "Total_Energy_Meter1_Inverter: " + Total_Energy_Meter1_Inverter.state)
  logInfo(logName, "Total_Energy_Returned_Meter1_Inverter: " + Total_Energy_Returned_Meter1_Inverter.state)
  logInfo(logName, "Reactive_Power_Meter1_Inverter: " + Reactive_Power_Meter1_Inverter.state)
  logInfo(logName, "Voltage_Meter1_Inverter: " + Voltage_Meter1_Inverter.state)
  logInfo(logName, "Current_Meter1_Inverter: " + Current_Meter1_Inverter.state)
  logInfo(logName, "Power_Factor_Meter1_Inverter: " + Power_Factor_Meter1_Inverter.state)
  logInfo(logName, "Last_Update_Meter1_Inverter: " + Last_Update_Meter1_Inverter.state)
  logInfo(logName, "Reset_Total_Meter1_Inverter: " + Reset_Total_Meter1_Inverter.state)
.....

Addendum:
It is noticeable that even with the UI (openhab+openhab-addons version 4.2.0~M2-1) for the Thing, only the channels

shelly:shellypro3em:pvInverter:meter1#currentWatts
shelly:shellypro3em:pvInverter:meter1#returnedKWH
shelly:shellypro3em:pvInverter:meter1#voltage
shelly:shellypro3em:pvInverter:meter1#current
shelly:shellypro3em:pvInverter:meter1#powerFactor

are suggested (for all three electricity meters). From the channels

channel="shelly:shellypro3em:pvInverter:meter1#totalKWH"
shelly:shellypro3em:pvInverter:meter1#reactiveWatts"

every trace is missing.


Addendum:
I have now compiled the latest version of shelly openhab-addon from mainbranch . It seems that the BaseHandler receives all data.

But still no output on the channels.

2024-05-19 13:41:22.163 [DEBUG] [y.internal.handler.ShellyBaseHandler] - shellypro3em-pvinverter: Channel device#deviceName updated with Pro3EM_PV (type class org.openhab.core.library.types.StringType).
2024-05-19 13:41:22.164 [DEBUG] [y.internal.handler.ShellyBaseHandler] - shellypro3em-pvinverter: Channel device#uptime updated with 1344 s (type class org.openhab.core.library.types.QuantityType).
2024-05-19 13:41:22.164 [DEBUG] [y.internal.handler.ShellyBaseHandler] - shellypro3em-pvinverter: Channel device#uptime updated with 1344 s (type class org.openhab.core.library.types.QuantityType).
2024-05-19 13:41:22.164 [DEBUG] [y.internal.handler.ShellyBaseHandler] - shellypro3em-pvinverter: Channel meter1#currentWatts updated with 0 W (type class org.openhab.core.library.types.QuantityType).
2024-05-19 13:41:22.164 [DEBUG] [y.internal.handler.ShellyBaseHandler] - shellypro3em-pvinverter: Channel meter1#totalKWH updated with 0 kWh (type class org.openhab.core.library.types.QuantityType).
2024-05-19 13:41:22.164 [DEBUG] [y.internal.handler.ShellyBaseHandler] - shellypro3em-pvinverter: Channel meter1#returnedKWH updated with 0 kWh (type class org.openhab.core.library.types.QuantityType).
2024-05-19 13:41:22.164 [DEBUG] [y.internal.handler.ShellyBaseHandler] - shellypro3em-pvinverter: Channel meter1#reactiveWatts updated with 0 W (type class org.openhab.core.library.types.QuantityType).
2024-05-19 13:41:22.164 [DEBUG] [y.internal.handler.ShellyBaseHandler] - shellypro3em-pvinverter: Channel meter1#voltage updated with 0 V (type class org.openhab.core.library.types.QuantityType).
2024-05-19 13:41:22.165 [DEBUG] [y.internal.handler.ShellyBaseHandler] - shellypro3em-pvinverter: Channel meter1#current updated with 0.027 A (type class org.openhab.core.library.types.QuantityType).
2024-05-19 13:41:22.165 [DEBUG] [y.internal.handler.ShellyBaseHandler] - shellypro3em-pvinverter: Channel meter1#powerFactor updated with 0 % (type class org.openhab.core.library.types.QuantityType).
2024-05-19 13:41:22.165 [DEBUG] [y.internal.handler.ShellyBaseHandler] - shellypro3em-pvinverter: Channel meter1#lastUpdate updated with 2024-05-19T13:41:22.000+0200 (type class org.openhab.core.library.types.DateTimeType).
.....
@hoinmic hoinmic added the bug An unexpected problem or unintended behavior of an add-on label May 18, 2024
@lsiepel lsiepel changed the title Some channels on Shelly Pro 3EM report NULL [shelly] Some channels on Shelly Pro 3EM report NULL May 19, 2024
@lsiepel
Copy link
Contributor

lsiepel commented May 20, 2024

Something you can look into @markus7017 ?

@markus7017 markus7017 self-assigned this May 24, 2024
@markus7017
Copy link
Contributor

Please switch to the latest DEV build and try again, check READMEbeta

4.2-DEV | 4.0.-DEV | 3.4.5-DEV | README | READMEbeta
Avdanced Users - Shelly Manager - Bugs/Features - API Doc | Firmware Index - Firmware Archive


Note: The DEV build is always newer than the version in the official Distro or Milestone builds. Current development is based on 4.1-SNAPSHOT, 4.0.x and 3.4.x might be outdated.

@hoinmic
Copy link
Author

hoinmic commented May 26, 2024

Hi Markus

I have implemented your solution. Unfortunately without success, the behaviour is still the same. The two channels "totalKWH" and "reactiveWatts" are missing.

I have done the following:

wget -O org.openhab.binding.shelly-4.2.0-SNAPSHOT.jar https://github.com/markus7017/myfiles/blob/master/shelly/org.openhab.binding.shelly-4.2.0-SNAPSHOT.jar?raw=true  

# -> removed all shelly things

# -> Uninstall Shelly binding form UI
openhab-cli console   -> feature:install openhab-transport-coap

systemctl stop openhab.service
sudo cp org.openhab.binding.shelly-4.2.0-SNAPSHOT.jar  /usr/share/openhab/addons
systemctl start openhab.service

openhab-cli console   -> bundle:list

added shelly pro 3em thing
....
290 │ Resolved │  80 │ 2.7.4                 │ Californium (Cf) Core
291 │ Resolved │  80 │ 2.7.4                 │ Californium (Cf) Element Connector
292 │ Resolved │  80 │ 2.7.4                 │ Californium (Cf) OSGi
293 │ Resolved │  80 │ 2.7.4                 │ Scandium (Sc) Core
294 │ Resolved │  80 │ 4.2.0.202405241838    │ openHAB Add-ons :: Bundles :: Shelly Binding

Screenshot from 2024-05-26 11-57-45

Sign up for free to join this conversation on GitHub. Already have an account? Sign in to comment
Labels
bug An unexpected problem or unintended behavior of an add-on
Projects
None yet
Development

No branches or pull requests

3 participants