Skip to content

Latest commit

 

History

History
721 lines (537 loc) · 37.5 KB

File metadata and controls

721 lines (537 loc) · 37.5 KB

Device Configuration Files

This directory contains device configuration files, describing the workings of supported devices. The files are in YAML format, and describe the mapping of Tuya DPs (Data Points) to HomeAssistant attributes.

Each Tuya device may correspond to one primary entity and any number of secondary entities in Home Assistant.

The Top Level

The top level of the device configuration defines the following:

name

The device should be named descriptively with a name the user would recognize. In general, the brand and model of the device should go under products, and a generic name for the type of device should go in the top level name.

products

Optional, for future use.

A list of products that this config applies to. Each product in the list must have an id specified, which corresponds to the productId or productKey (depending on where you are getting it from) in Tuya info. This is available from the Tuya developer web portal listing for your device, or when using UDP discovery (via tinytuya). In future it is intended that UDP discovery will be used to more precisely match devices to configs, so it is recommended to report these if you can find them when requesting a new device. Each listing can also have an optional name, which is intended to specify the specific brand and model name or number of the matching device. In future when local discovery is implemented to discover products by id, this name will be displayed on discovery, and be available as manufacturer and model info in device settings.

primary_entity

This contains the configuration for one Home Assistant entity which is considered the main entity for the device. For example, if the device is a heater, this would be a climate entity.

The configuration for entities is detailed in its own section below.

secondary_entities

Optional.

This contains a list of additional Home Assistant entities providing additional functionality beyond the capabilities of the primary entity. Examples include lighting control for display panels as a Home Assistant light entity, child locks as a Home Assistant lock entity, or additional toggles as Home Assistant switch entities.

The configuration for secondary entities is the same as primary entities, and is detailed in the section below.

Entity configuration

entity

The Home Assistant entity type being configured. Currently supported types are climate, switch, light, lock. Functionality for these entities is limited to that which has been required for the devices until now and may need to be extended for new devices. In particular, the light and lock entities have only been used for simple secondary entities, so only basic functionality is implemented.

class

Optional.

For some entity types, a device class can be set, for example switch entities can have a class of outlet. This may slightly alter the UI behaviour. For most entities, it will alter the default icon, and for binary sensors also the state that off and on values translate to in the UI.

translation_key / translation_only_key

Optional

A key used to define strings and icons for this entity. If this is used, the name can be omited and instead defined in the translations files.

translation_key will be used to generate IDs when there is no name defined. If the intention is to have an unnamed entity, or to inherit from class, then use translation_only_key instead (this is mostly useful to retain backward compatibility where translation_key is used to define icons and attribute strings but not the entity name.

category

Optional.

This specifies the entity category of the entity. Entities can be categorized as config or diagnostic to restrict where they appear automatically in Home Assistant.

dps

This is a list of the definitions for the Tuya DPs associated with attributes of this entity. There should be one list entry for each supported DPs reported by the device.

The configuration of DPs entries is detailed in its own section below.

name

Optional.

The name associated with this entity can be set here. If no name is set, it will inherit the name at the top level. This is mostly useful for overriding the name of secondary entities to give more information about the purpose of the entity, as the generic type with the top level name may not be sufficient to describe the function.

mode

Optional. For number entities, default="auto", for others, None

For number entities, this can be used to force slider or box as the input method. The default auto uses a slider if the range is small enough, or a box otherwise.

DPs configuration

id

Every DP must have a numeric ID matching the DP ID in the Tuya protocol.

type

The type of data returned by the Tuya API. Can be one of the following:

  • string can contain arbitrary text.
  • boolean can contain the values True or False.
  • integer can contain only numbers. Integers can have range set on them, be scaled and steped
  • bitfield is a special case of integer, where the bits that make up the value each has individal meaning.
  • unixtime is a special case of integer, where the device uses a unix timestamp (seconds since 1970-01-01 00:00), which is converted to a datetime for Home Assistant
  • base64 is a special case of string, where binary data is base64 encoded. Platforms that use this type will need special handling to make sense of the data.
  • hex is a special case of string, where binary data is hex encoded. Platforms that use this type will need special handling to make sense of the data.
  • json is a special case of string, where multiple data points are encoded in json format in the string. Platforms that use this type will need special handling to make sense of the data.
  • float can contain floating point numbers. No known devices use this, but it is supported if needed.

name

The name given to the attribute in Home Assistant. Certain names are used by the Home Assistant entities for specific purposes. If a name is not recognized as a standard attribute by the entitiy implementation, the attribute will be returned as a readonly custom attribute on the entity. If you need non-standard attributes to be able to be set, you will need to use a secondary entity for that.

readonly

Optional, default false.

A boolean setting to mark attributes as readonly. If not specified, the default is false. If set to true, the attributes will be reported to Home Assistant, but attempting to set them will result in an error. This is only needed in contexts where it would normally be possible to set the value. If you are creating a sensor entity, or adding an attribute of an entity which is inherently read-only, then you do not need to specify this.

optional

Optional, default false.

A boolean setting to mark attributes as optional. This allows a device to be matched even if it is not sending the dp at the time when adding a new device. It can also be used to match a range of devices that have variations in the extra attributes that are sent.

persist

Optional, default true.

Whether to persist the value if the device does not return it on every status refresh. Some devices don't return every value on every status poll. In most cases, it is better to remember the previous value, but in some cases the dp is used to signal an event, so when it is next sent, it should trigger automations even if it is the same value as previously sent. In that case the value needs to go to null in between when the device is not sending it.

force

Optional, default false.

A boolean setting to mark dps as requiring an explicit update request to fetch. Many energy monitoring smartplugs require this, without a explicit request to update them, such plugs will only return monitoring data rarely or never. Devices can misbehave if this is used on dps that do not require it. Use this only where needed, and generally only on read-only dps.

precision

Optional, default None.

For integer dps that are sensor values, the suggested precision for display in Home Assistant can be specified. If unspecified, the Home Assistant will use the native precision, which is calculated based on the scale of the dp so as to provide distinct values with as few decimal places as possible. For example a scale of 3 will result in one decimal place by default, (values displayed as x.3, x.7 rather than x.33333333 and x.666666) but you could override that to 2 or 0 with by specifying the precision explicitly.

mapping

Optional. Must be a list with each item starting with a - (a dash and a space): This can be used to define a list of additional rules that modify the DP to Home Assistant attribute mapping to something other than a one to one copy.

The rules can range from simple value substitution to complex relationships involving other attributes.

hidden

Optional, default false. This can be used to define DPs that do not directly expose Home Assistant attributes. When set to true, no attribute will be sent. A name should still be specified and the attribute can be referenced as a constraint from mapping rules on other attributes to implement complex mappings.

An example of use is a climate device, where the Tuya device keeps separate temperature settings for different Normal and Eco preset modes. The Normal temperature setting is exposed through the standard temperature Home Assistant attribute on the climate device, but the eco_temperature setting on a different DP is set to hidden. Mapping Rules are used on the temperature attribute to redirect to eco_temperature when preset_mode is set to Eco.

range

Optional, may be required in some contexts, may have defaults in others.

For integer attributes that are not readonly, a range can be set with min and max values that will limit the values that the user can enter in the Home Assistant UI. This can also be set in a mapping or conditions block.

unit

Optional, default="C" for temperature dps on climate devices.

For temperature dps, some devices will use Fahrenhiet. This needs to be indicated back to HomeAssistant by defining unit as "F". For sensor entities, see the HomeAssistant developer documentation for the full list of possible units (C and F are automatically translated to their Unicode equivalents, other units are currently ASCII so can be easily entered directly).

class

Optional.

For sensors, this sets the state class of the sensor (measurement, total or total_increasing)

format

Optional.

For base64 and hex types, this specifies how to decode the binary data (after hex or base64 decoding). This is a container field, the contents of which should be a list consisting of name, bytes and range fields. range is as described above. bytes is the number of bytes for the field, which can be 1, 2, or 4. name is a name for the field, which will have special handling depending on the device type.

mask

Optional.

For base64 and hex types, this specifies how to extract a single numeric value from the binary data. The value should be a hex bit mask (eg 00FF00 to extract the middle byte of a 3 byte value). Unlike format, this does not require special handling in the entity platform, as only a single value is being extracted.

endianness

Optional, default="big"

For base64 and hex types, this specifies the endianess of the data and mask. Could be "big" or "little".

Mapping Rules

Mapping rules can change the behavior of attributes beyond simple copying of DP values to attribute values. Rules can be defined without a dps_val to apply to all values, or a list of rules that apply to particular dp values can be defined to change only particular cases. Rules can even depend on the values of other elements.

dps_val

Optional, if not provided, the rule is a default that will apply to all values not covered by their own dps_val rule.

dps_val defines the DP value that each rule in the list applies to. This can be used to map specific values from the Tuya protocol into attribute values that have specific meaning in Home Assistant. For example, climate entities in Home Assistant define modes "off", "heat", "cool", "heat_cool", "auto" and "dry". But in the Tuya protocol, a simple heater just has a boolean off/on switch. A dps_val of null can be used to specify a value to be assumed when a dp is not being returned by the device, to avoid None in some locations where that causes an issue such as entities showing as unavailable. Such a mapping is one-way, the value will not be mapped back to a null when setting the dp.

value

Optional.

This can be used to set the attribute value seen by Home Assistant to something different than the DP value from the Tuya protocol. Normally it will be used with dps_val to map from one value to another. Without dps_val it will one-way map all otherwise unmapped dps values to the specified value. This can be useful for a binary_sensor.

hidden

Optional, default=false

When set to true, the mapping value is hidden from the list of all values. This can be used for items that should not be available for selection by the user but you still want to map for feedback coming from the device. For example, some devices have a "Manual" mode, which is automatically selected when adjustments are made to other settings, but should not be available as an explicit mode for the user to select.

scale

Optional, default=1.

This can be used in an integer dp mapping to scale the values. For example some climate devices represent the temperature as an integer in tenths of degrees, and require a scale of 10 to convert them to degrees expected by Home Assistant. The scale can also be the other way, for a fan with speeds 1, 2 and 3 as DP values, this can be converted to a percentage with a scale of 0.03.

invert

Optional, default=False.

This can be used in an integer dp mapping to invert the range. For example, some cover devices have an opposite idea of which end of the percentage scale open and closed are from what Home Assistant assumes. To use this mapping option, a range must also be specified for the dp.

step

Optional, default=1.

This can be used in an integer dp mapping to make values jump by a specific step. It can also be set in a conditions block so that the steps change only under certain conditions. An example is where a value has a range of 0-100, but only allows settings that are divisible by 10, so a step of 10 would be set.

target_range

Optional, has min and max child attributes, like range

A target range is used together with range on a numeric value, to map the value into a new range. Unlike scale, this can shift the value as well as scale it into the new range. Color temperature is a major use of this, as Tuya devices often use a range of 0 - 100, 0 - 255 or 0 - 1000, and this needs to be mapped to the Kelvin like 2200 - 6500.

This should normally only be used on a default mapping, as the code that uses this feature often needs to inform HA of the min and max values for the UI, which may not handle multipe different mappings across the range.

icon

Optional. Deprecated since HA 2024.2 (use translation_key and icons.json to define icons)

This can be used to override the icon. Most useful with a dps_val which indicates a change from normal operating mode, such as "fan-only", "defrosting", "tank-full" or some error state.

icon_priority

Optional. Default 10. Lower numbers mean higher priorities. Deprecated, icons should be defined using icons.json and translation_key since HA 2024.2

When a number of rules on different attributes define icon changes, you may need to control which have priority over the others. For example, if the device is off, probably it is more important to indicate that than whether it is in fan-only or heat mode. So in the off/on DP, you might give a priority of 1 to the off icon, 3 to the on icon, and in the mode DP you could give a priority of 2 to the fan icon, to make it override the normal on icon, but not the off icon. If you don't specify any priorities, the icons will all get the same priority, so if any overlap exists in the rules, it won't always be predictable which icon will be displayed.

value_redirect

Optional.

When value_redirect is set, the value of the attribute and any attempt to set it will be redirected to the named attribute instead of the current one.

An example of how this can be useful is where a Tuya heater has a dp for the target temperature in normal mode, and a different dp for the target temperature is "eco" mode. Depending on the preset_mode, you need to use one or the other. But Home Assistant just has one temperature attribute for setting target temperature, so the mapping needs to be done before passing to Home Assistant.

value_mirror

Optional.

When value_mirror is set, the value of the attribute will be redirected to the current value of the named attribute. Unlike value_redirect, this does not redirect attempts to set the dp to the redirected dp, but when used in a map, this can make the mapping dynamic.

An example of how this can be useful is where a thermostat can be configured to control either a heating or cooling device, but it is not expected to change this setting during operation. Once set up, the hvac_mode dp can have a mapping that mirrors the value of the configuration dp.

invalid

Optional, default false.

Invalid set to true allows an attribute to temporarily be set read-only in some conditions. Rather than passing requests to set the attribute through to the Tuya protocol, attempts to set it will throw an error while it meets the conditions to be invalid. It does not make sense to set this at mapping level, as it would cause a situation where you can set a value then not be able to unset it. Instead, this should be used with conditions, below, to make the behaviour dependent on another DP, such as disabling fan speed control when the preset is in sleep mode (since sleep mode should force low).

default

Optional, default false.

Default set to true allows an attribute to be set as the default value. This is used by some entities when an argument is not provided to a service call but the attribute is required to be set to function correctly. An example is the siren entity which uses the tone attribute to turn on and off the siren, but when turn_on is called without any argument, it needs to pick a default tone to use to turn on the siren.

constraint

Optional, always paired with conditions. Default if unspecified is the current attribute

If a rule depends on an attribute other than the current one, then constraint can be used to specify the element that conditions applies to. constraint can also refer back to the same attribute - this can be useful for specifying conditional mappings, for example to support two different variants of a device in a single config file, where the only difference is the way they represent enum attributes.

conditions

Optional, usually paired with constraint.

Conditions defines a list of rules that are applied based on the constraint attribute. The contents are the same as Mapping Rules, but dps_val applies to the attribute specified by constraint, and also can be a list of values to match as well rather than a single value. All others act on the current attribute as they would in the mapping. Although conditions are specified within a mapping, they can also contain a mapping of their own to override that mapping. These nested mappings are limited to simple dps_val to value substitutions, as more complex rules would quickly become too complex to manage.

When setting a dp which has conditions attached, the behaviour is slightly different depending on whether the constraint dp is readonly or not.

For non-readonly constraints that specify a single dps_val, the constraint dp will be set along with the target dp so that the first condition with a value matching the target value is met.

For readonly constraints, the condition must match the constraint dp's current value for anything to be set.

Example

  ...
  name: target_dp
  mapping:
    - dps_val: 1
      constraint: constraint_dp
      conditions:
        - dps_val: a
          value: x
        - dpa_val: c
          value: z
    - dps_val: 2
      constraint: constraint_dp
      conditions:
        - dps_val: b
          value: x
        - dps_val: c
          value: y

If constraint_dp is not readonly:

constraint_dp current dps_val target_dp target value dps set
a x target_dp: 1, constraint_dp: a
a y target_dp: 2, constraint_dp: c
a z target_dp: 1, constraint_dp: c
b x target_dp: 1, constraint_dp: a
b y target_dp: 2, constraint_dp: c
b z target_dp: 1, constraint_dp: c
c x target_dp: 1, constraint_dp: a
c y target_dp: 2, constraint_dp: c
c z target_dp: 1, constraint_dp: c

If constraint_dp is readonly:

current constraint_dp target target_dp dps set
a x target_dp: 1
a y -
a z -
b x target_dp: 2
b y -
b z -
c x -
c y target_dp: 2
c z target_dp: 1

Note that each condition must specify a dps_val to match againt. If you want to specify a default match, do it outside the conditions.

    mapping:
      - dps_val: some_value
        value: defaulted
        constraint: other_dp
        conditions:
          - dps_val: other_value
            value: overridden

Entity types

Entities have specific mappings of dp names to functions. Any unrecognized dp name is added to the entity as a read-only extra attribute, so can be observed and queried from HA, but if you need to be able to change it, you should split it into its own entity of an appropriate type (number, select, switch for example).

If the type of dp does not match the expected type, a mapping should be provided to convert. Note that "on" and "off" require quotes in yaml, otherwise it they are interpretted as true/false.

Many entity types support a class attribute which may change the UI behaviour, icons etc. See the HA documentation for the entity type to see what is valid (these may expand over time)

alarm_control_panel

  • alarm_state (required, string) the alarm state, used to report and change the current state of the alarm. Expects values from the set disarmed, armed_home, armed_away, armed_night, armed_vacation, armed_custom_bypass, pending, arming, disarming, triggered. Other states are allowed for read-only status, but only the armed... and disarmed states are available as commands.
  • trigger (optional, boolean) used to trigger the alarm remotely for test or panic button etc.

binary_sensor

  • sensor (required, boolean) the dp to attach to the sensor.

button

  • button (required, boolean) the dp to attach to the button. Any read value will be ignored, but the dp is expected to be present for device detection unless set to optional. A value of true will be sent for a button press, map this to the desired dps_val if a different value is required.

camera

  • motion_enable (optional, boolean) a dp that enables and disables motion detection features built into the camera.
  • record (optional, boolean) a dp that turns reecording on and off.
  • snapshot (optional, base64 string) a dp that returns a snapshot image. from the camera.
  • switch (optional, boolean) a dp to turn the camera on and off.

NOTE: tuya-local does not directly support video streaming from cameras. Some cameras provide ONVIF or WebRTC compliant streams locally which you can use the relevant integrations to capture, others may be cloud-only.

climate

  • current_temperature (optional, number) a dp that reports the current temperature.
  • current_humidity (optional, number) a dp that reports the current humidity (%).
  • fan_mode (optional, mapping of strings) a dp to control the fan mode if available. Any value is allowed, but HA has some standard modes: "on", "off", auto, low, medium, high, top, middle, focus, diffuse
  • humidity (optional, number) a dp to control the target humidity if available. (%)
  • hvac_mode (optional, mapping of strings) a dp to control the mode of the device. Possible values are: "off", cool, heat, heat_cool, auto, dry, fan_only
  • hvac_action (optional, string) a dp that reports the current action of the device. Possible values are: "off", idle, cooling, heating, drying, fan
  • preset_mode (optional, mapping of strings) a dp to control preset modes of the device. Any value is allowed, but HA has some standard presets: none, eco, away, boost, comfort, home, sleep, activity
  • swing_mode (optional, mapping of strings) a dp to control swing modes of the device. Possible values are: "off", vertical, horizontal
  • temperature (optional, number) a dp to set the target temperature of the device. A unit may be specified as part of the attribute if a temperature_unit dp is not available, if not the default unit configured in HA will be used.
  • target_temp_high (optional, number) a dp to set the upper temperature range of the device. This dp should be paired with target_temp_low, and is mutually exclusive with temperature
  • target_temp_low (optional, number) a dp to set the lower temperature range of the device.
  • temperature_unit (optional, string) a dp that specifies the unit the device is configured for. Values should be mapped to "C" or "F" (case sensitive) - often the device will use a boolean or lower case for this
  • min_temperature (optional, number) a dp that specifies the minimum temperature that can be set. Some devices provide this, otherwise a fixed range on the temperature dp can be used.
  • max_temperature (optional, number) a dp that specifies the maximum temperature that can be set.

cover

Either position or open should be specified.

  • position (optional, number 0-100): a dp to control the percentage that the cover is open. 0 means completely close, 100 means completely open.
  • control (optional, mapping of strings): a dp to control the cover. Mainly useful if position cannot be used. Valid values are open, close, stop
  • action (optional, string): a dp that reports the current state of the cover. Special values are opening, closing
  • open (optional, boolean): a dp that reports if the cover is open. Only used if position is not available.

fan

  • switch (optional, boolean): a dp to control the power state of the fan
  • preset_mode (optional, mapping of strings): a dp to control different modes of the fan. Values "off", low, medium, high used to be handled specially by HA as deprecated speed aliases. If these are the only "presets", consider mapping them as speed values instead, as voice assistants will respond to phrases like "turn the fan up/down" for speed.
  • speed (optional, number): a dp to control the speed of the fan (%). if a range is supplied, it will be automatically scaled to the 0-100 range. if a mapping is used for dicrete steps, the values must be mapped within that range.
  • oscillate (optional, boolean): a dp to control whether the fan will oscillate or not.
  • direction (optional, string): a dp to control the spin direction of the fan. Valid values are forward, reverse.

humidifier

Humidifer can also cover dehumidifiers (use class to specify which).

  • switch (optional, boolean): a dp to control the power state of the fan
  • mode (optional, mapping of strings): a dp to control preset modes of the device
  • humidity (optional, number): a dp to control the target humidity of the device
  • current_humidity (optional, number): a dp to report the current humidity measured by the device

lawn_mower

  • activity (required, string): a dp to report the current activity of the mower. Valid activities are mowing, paused, docked, error (from LawnMowerActivities in https://github.com/home-assistant/core/blob/dev/homeassistant/components/lawn_mower/const.py). Any additional activities should be mapped to one of those, and exposed through an extra attribute or sensor entity that shows all the statuses that the mower is reporting.

  • command (required, string): a dp to send commands to the mower. Recognised commands are start_mowing, pause and dock. Any additional commands should be implemented via a button or select entity.

light

  • switch (optional, boolean): a dp to control the on/off state of the light

  • brightness (optional, number): a dp to control the dimmer if available. If a range is provided, the value will be automatically scaled into the 0-255 range for HA, so there is no need to provide a scale. If there is a fixed list of mappings, the values should be between 0 (off) and 255 (full brightness). If there is no switch dp, a brightness of 0 will be sent to turn the light off.

  • color_temp (optional, number): a dp to control the color temperature if available. See target_range above for mapping Tuya's range into Kelvin.

  • rgbhsv (optional, hex): a dp to control the color of the light, using encoded RGB and HSV values. The format field names recognized for decoding this field are r, g, b, h, s, v.

  • color_mode (optional, mapping of strings): a dp to control which mode to use if the light supports multiple modes. Special values: white, color_temp, hs, xy, rgb, rgbw, rgbww, others will be treated as effects, Note: only white, color_temp and hs are currently supported, others listed above are reserved and may be implemented in future when the need arises. If no color_mode dp is available, a single supported color mode will be calculated based on which of the above dps are available.

  • effect (optional, mapping of strings): a dp to control effects / presets supported by the light. Note: If the light mixes in color modes in the same dp, color_mode should be used instead. If the light contains both a separate dp for effects/scenes/presets and a mix of color_modes and effects (commonly scene and music) in the color_mode dp, then a separate select entity should be used for the dedicated dp to ensure the effects from color_mode are selectable.

lock

The unlock... dps below are normally integers, but can also be boolean, in which case no information will be available about which specific credential was used to unlock the lock.

  • lock (optional, boolean): a dp to control the lock state: true = locked, false = unlocked
  • unlock_fingerprint (optional, integer): a dp to identify the fingerprint used to unlock the lock.
  • unlock_password (optional, integer): a dp to identify the password used to unlock the lock.
  • unlock_temp_pwd (optional, integer): a dp to identify the temporary password used to unlock the lock.
  • unlock_dynamic_pwd (optional, integer): a dp to identify the dynamic password used to unlock the lock.
  • unlock_offline_pwd (optional, integer): a dp to identify the offline password used to unlock the lock.
  • unlock_card (optional, integer): a dp to identify the card used to unlock the lock.
  • unlock_app (optional, integer): a dp to identify the app used to unlock the lock.
  • unlock_face (optional, integer): a dp to identify the face used to unlock the lock.
  • unlock_key (optional, integer): a dp to identify the key used to unlock the lock.
  • unlock_ble (optional, integer): a dp to identify the BLE device used to unlock the lock.
  • unlock_voice (optional, integer): a dp to identify the voice assistant user used to unlock the lock.
  • request_unlock (optional, integer): a dp to signal that a request has been made to unlock, the value should indicate the time remaining for approval.
  • approve_unlock (optional, boolean): a dp to unlock the lock in response to a request.
  • request_intercom (optional, integer): a dp to signal that a request has been made via intercom to unlock, the value should indicate the time remaining for approval.
  • approve_intercom (optional, boolean): a dp to unlock the lock in response to an intercom request.
  • jammed (optional, boolean): a dp to signal that the lock is jammed.

number

  • value (required, number): a dp to control the number that is set.
  • unit (optional, string): a dp that reports the units returned by the number. This may be useful for devices that switch between C and F, otherwise a fixed unit attribute on the value dp can be used.
  • minimum (optional, number): a dp that reports the minimum the number can be set to. This may be used as an alternative to a range setting on the value dp if the range is dynamic
  • maximum (optional, number): a dp that reports the maximum the number can be set to. This may be used as an alternative to a range setting on the value dp if the range is dynamic

remote

  • send (required, accepts a string): a dp to send remote codes.
  • receive (optional, returns strings): a dp to receive learned commands on. If not supplied, the remote.learn_command service call will not be available.
  • control (optional, accepts strings "send_ir", "study", "study_exit"): a dp to send commands seperately from ir codes. If not supplied, commands will be JSON formatted and sent through the send dp.
  • delay (optional, accepts numbers): a dp to set the delay in ms between buttons when there are multiple in the send string. This is only used when a separate control dp is also supplied, otherwise the parameter is included in the JSON sent to the send dp.
  • code_type (optional, accepts integers): a dp to set the type of code being sent. The current implementation only supports type 0. This is only used when a separate control dp is also supplied, otherwise the parameter is included in the JSON sent to the send dp.

select

  • option (required, mapping of strings): a dp to control the option that is selected.

sensor

  • sensor (required, number or string): a dp that returns the current value of the sensor.
  • unit (optional, string): a dp that returns the unit returned by the sensor. This may be useful for devices that switch between C and F, otherwise a fixed unit attribute on the sensor dp can be used.

siren

  • tone (required, mapping of strings): a dp to report and control the siren tone. As this is used to turn on and off the siren, it is required. If this does not fit your siren, the underlying implementation will need to be modified. The value "off" will be used for turning off the siren, and will be filtered from the list of available tones. One value must be marked as default: true so that the turn_on service with no commands works.
  • volume (optional, float in range 0.0-1.0): a dp to control the volume of the siren (probably needs a scale and step applied, since Tuya devices will probably use an integer, or strings with fixed values).
  • duration (optional, integer): a dp to control how long the siren will sound for.

switch

  • switch (required, boolean): a dp to control the switch state.

vacuum

  • status (required, mapping of strings): a dp to report and control the status of the vacuum.
  • command (optional, mapping of strings): a dp to control the statuss of the vacuum. If supplied, the status dp is only used to report the state. Special values: return_to_base, clean_spot, others are sent as general commands
  • locate (optional, boolean): a dp to trigger a locator beep on the vacuum.
  • power (optional, boolean): a dp to switch full system power on and off
  • activate (optional, boolean): a dp to start and pause the vacuum
  • direction_control (optional, mapping of strings): a dp that is used for directional commands These are additional commands that are not part of status. They can be sent as general commands from HA.
  • error (optional, bitfield): a dp that reports error status. As this is mapped to a single "fault" state, you could consider separate binary_sensors to report on individual errors

valve

  • valve (required, boolean or integer): a dp that reports the current state of the valve, and if not readonly, can also be used to set the state. If a number, it should be a percentage between 0 and 100 indicating how far open the valve is. If a boolean, it should indicate open (true) or closed (false).

water_heater

  • current_temperature (optional, number): a dp that reports the current water temperature.

  • operation_mode (optional, mapping of strings): a dp to report and control the operation mode of the water heater. If away is one of the modes, another mode must be marked as default: true to that the away_mode_off service knows which mode to switch out of away mode to.

  • temperature (optional, number): a dp to control the target water temperature of the water heater. A unit may be specified as an attribute if the temperature_unit dp is not available, otherwise the default of HA's current setting will be used.

  • temperature_unit (optional, string): a dp that reports the unit the device is configured for. Values should be mapped to "C" or "F" (case sensitive) - often the device will use a boolean or lower case for this

  • min_temperature (optional, number): a dp that reports the minimum temperature the water heater can be set to, in case this is not a fixed value.

  • max_temperature (optional, number): a dp that reports the maximum temperature the water heater can be set to, in case this is not a fixed value.

  • away_mode (optional, boolean): a dp to control whether the water heater is in away mode.