Skip to content
New issue

Have a question about this project? Sign up for a free GitHub account to open an issue and contact its maintainers and the community.

By clicking “Sign up for GitHub”, you agree to our terms of service and privacy statement. We’ll occasionally send you account related emails.

Already on GitHub? Sign in to your account

Support of Sunny Boy Storage 3.7 #528

Open
sbf- opened this issue Mar 9, 2022 Discussed in #518 · 1 comment
Open

Support of Sunny Boy Storage 3.7 #528

sbf- opened this issue Mar 9, 2022 Discussed in #518 · 1 comment

Comments

@sbf-
Copy link
Collaborator

sbf- commented Mar 9, 2022

Discussed in #518

Originally posted by dh2wq January 30, 2022
Hi,
many thanks for this great tool. For me, it works great for Power Values, but I don't get any information regarding the battery.
I get following information from the inverter?

Device Class:     Battery Inverter
Device Type:      Sunny Boy Storage 3.7
Software Version: 03.12.33.R

But for Battery Charge Status or general Battery Info I get just the Packet Status 21 which I understand means "command not supported".

Packet status: 21
getBatteryChargeStatus returned an error: 21
Packet status: 21
getBatteryInfo returned an error: 21

I checked the addresses of the return values in the diff description of the sunny portal, and they seem to be the same, but the command may be different. Are the commands somewhere available? I haven't found on the web so far.

I also get odd response for getSpotDCPower and getSpotDCVoltage (I dont see if this comes from Sunny Boy Storage 3.7 or Sunny Tripower 10.0)

Packet status: 21
getSpotDCPower returned an error: 21
Packet status: 21
getSpotDCVoltage returned an error: 21
00464B01 28 Sun Jan 30 19:45:38 2022 'Grid voltage phase L1 against L2' NaN NaN NaN NaN
00464C01 28 Sun Jan 30 19:45:38 2022 'Grid voltage phase L2 against L3' NaN NaN NaN NaN
00464D01 28 Sun Jan 30 19:45:38 2022 'Grid voltage phase L3 against L1' NaN NaN NaN NaN
00464E01 28 Sun Jan 30 19:45:52 2022 '' 95 95 95 95
00464B07 28 Sun Jan 30 19:45:52 2022 'Grid voltage phase L1 against L2' NaN NaN NaN NaN
00464C07 28 Sun Jan 30 19:45:52 2022 'Grid voltage phase L2 against L3' NaN NaN NaN NaN
00464D07 28 Sun Jan 30 19:45:52 2022 'Grid voltage phase L3 against L1' NaN NaN NaN NaN
00464E07 28 Sun Jan 30 19:45:52 2022 '' 95 95 95 95

I do have basic skills in programming and may support here, but I am not keen enough to just loop commands to the Inverter for now. I am scared I screw something up.

BR
Olli

@mgehre
Copy link

mgehre commented Apr 6, 2022

Also happens for SBS 2.5

Sign up for free to join this conversation on GitHub. Already have an account? Sign in to comment