-
Notifications
You must be signed in to change notification settings - Fork 390
/
issu_process.sh
executable file
·250 lines (213 loc) · 7.8 KB
/
issu_process.sh
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
145
146
147
148
149
150
151
152
153
154
155
156
157
158
159
160
161
162
163
164
165
166
167
168
169
170
171
172
173
174
175
176
177
178
179
180
181
182
183
184
185
186
187
188
189
190
191
192
193
194
195
196
197
198
199
200
201
202
203
204
205
206
207
208
209
210
211
212
213
214
215
216
217
218
219
220
221
222
223
224
225
226
227
228
229
230
231
232
233
234
235
236
237
238
239
240
241
242
243
244
245
246
247
248
249
250
#!/usr/bin/env bash
function issu_contrail_switch_compute_node {
route -n
openstack-config --set /etc/contrail/contrail-vrouter-agent.conf DISCOVERY server $1
openstack-config --set /etc/contrail/supervisord_vrouter_files/contrail-vrouter-agent.ini program:contrail-vrouter-agent autostart true
openstack-config --set /etc/contrail/supervisord_vrouter_files/contrail-vrouter-agent.ini program:contrail-vrouter-agent killasgroup true
openstack-config --set /etc/contrail/contrail-vrouter-nodemgr.conf DISCOVERY server $1
for i in `ls /etc/contrail/contrail-tor-agent-*`; do echo $i; openstack-config --set $i DISCOVERY server $1; done
service supervisor-vrouter status; service supervisor-vrouter stop; service supervisor-vrouter status; rmmod -w vrouter;modprobe vrouter;service supervisor-vrouter start
contrail-status
route -n
}
function issu_contrail_prepare_compute_node {
route -n
openstack-config --del /etc/contrail/supervisord_vrouter_files/contrail-vrouter-agent.ini program:contrail-vrouter-agent autostart
openstack-config --del /etc/contrail/supervisord_vrouter_files/contrail-vrouter-agent.ini program:contrail-vrouter-agent killasgroup
contrail-status
}
function issu_contrail_set_supervisord_config_files {
local cmd="openstack-config --set /etc/contrail/supervisord_config_files/$1.ini program:$1"
$cmd autostart $2
$cmd autorestart $2
$cmd killasgroup $2
}
function issu_contrail_prepare_new_control_node {
contrail-status
issu_contrail_set_supervisord_config_files 'contrail-device-manager' 'false'
issu_contrail_set_supervisord_config_files 'contrail-svc-monitor' 'false'
issu_contrail_set_supervisord_config_files 'contrail-schema' 'false'
openstack-config --set /etc/contrail/supervisord_config_files/contrail-config-nodemgr.ini eventlistener:contrail-config-nodemgr autorestart false
openstack-config --set /etc/contrail/supervisord_config_files/contrail-config-nodemgr.ini eventlistener:contrail-config-nodemgr autostart false
contrail-status
service supervisor-config restart
contrail-status
service supervisor-config stop
contrail-status
}
function issu_contrail_post_new_control_node {
contrail-status
#openstack-config --set /etc/contrail/supervisord_config.conf include files \"/etc/contrail/supervisord_config_files/*.ini\"
issu_contrail_set_supervisord_config_files 'contrail-device-manager' 'true'
issu_contrail_set_supervisord_config_files 'contrail-svc-monitor' 'true'
issu_contrail_set_supervisord_config_files 'contrail-schema' 'true'
openstack-config --del /etc/contrail/supervisord_config_files/contrail-config-nodemgr.ini eventlistener:contrail-config-nodemgr autorestart
openstack-config --del /etc/contrail/supervisord_config_files/contrail-config-nodemgr.ini eventlistener:contrail-config-nodemgr autostart
service supervisor-config restart
contrail-status
}
function issu_pre_sync {
contrail-issu-pre-sync -c /etc/contrail/contrail-issu.conf
}
function issu_run_sync {
local cmd='openstack-config --set /etc/supervisor/conf.d/contrail-issu.conf program:contrail-issu'
touch /etc/supervisor/conf.d/contrail-issu.conf
$cmd command 'contrail-issu-run-sync --conf_file /etc/contrail/contrail-issu.conf'
$cmd numprocs 1
openstack-config --set /etc/supervisor/conf.d/contrail-issu.conf program:contrail-issu process_name '%(process_num)s'
$cmd redirect_stderr true
openstack-config --set /etc/supervisor/conf.d/contrail-issu.conf program:contrail-issu stdout_logfile '/var/log/issu-contrail-run-sync-%(process_num)s-stdout.log'
openstack-config --set /etc/supervisor/conf.d/contrail-issu.conf program:contrail-issu stderr_logfile '/dev/null'
$cmd priority 440
$cmd autostart true
$cmd killasgroup false
$cmd stopsignal KILL
$cmd exitcodes 0
service supervisor restart
}
function issu_post_sync {
rm -f /etc/supervisor/conf.d/contrail-issu.conf
service supervisor restart
contrail-issu-post-sync -c /etc/contrail/contrail-issu.conf
contrail-issu-zk-sync -c /etc/contrail/contrail-issu.conf
}
function issu_contrail_generate_conf {
local myfile="/tmp/contrail-issu.conf"
issu_contrail_get_and_set_old_conf $1 $myfile
issu_contrail_get_and_set_new_conf $2 $myfile
echo $1 $2
}
function issu_contrail_get_and_set_old_conf {
local get_old_cmd="openstack-config --get $1 DEFAULTS"
local has_old_cmd="openstack-config --has $1 DEFAULTS"
local set_cmd="openstack-config --set $2 DEFAULTS"
cmd="$get_old_cmd cassandra_server_list"
val=$($cmd)
$set_cmd old_cassandra_address_list "$val"
cmd="$get_old_cmd zk_server_ip"
val=$($cmd)
$set_cmd old_zookeeper_address_list "$val"
cmd="$has_old_cmd rabbit_user"
val=$($cmd)
if [ $val == 1 ]
then
cmd="$get_old_cmd rabbit_user"
val=$($cmd)
$set_cmd old_rabbit_user "$val"
fi
cmd="$has_old_cmd rabbit_password"
val=$($cmd)
if [ $val == 1 ]
then
cmd="$get_old_cmd rabbit_password"
val=$($cmd)
$set_cmd old_rabbit_password "$val"
fi
cmd="$has_old_cmd rabbit_vhost"
val=$($cmd)
if [ $val == 1 ]
then
cmd="$get_old_cmd rabbit_vhost"
val=$($cmd)
$set_cmd old_rabbit_vhost "$val"
fi
cmd="$has_old_cmd rabbit_ha_mode"
val=$($cmd)
if [ $val == 1 ]
then
cmd="$get_old_cmd rabbit_ha_mode"
val=$($cmd)
$set_cmd old_rabbit_ha_mode "$val"
fi
cmd="$has_old_cmd rabbit_port"
val=$($cmd)
if [ $val == 1 ]
then
cmd="$get_old_cmd rabbit_port"
val=$($cmd)
$set_cmd old_rabbit_port "$val"
fi
cmd="$has_old_cmd rabbit_server"
val=$($cmd)
if [ $val == 1 ]
then
cmd="$get_old_cmd rabbit_server"
val=$($cmd)
$set_cmd old_rabbit_address_list "$val"
fi
cmd="$has_old_cmd cluster_id"
val=$($cmd)
if [ $val == 1 ]
then
cmd="$get_old_cmd cluster_id"
val=$($cmd)
$set_cmd odb_prefix "$val"
fi
}
function issu_contrail_get_and_set_new_conf {
local get_new_cmd="openstack-config --get $1 DEFAULTS"
local set_cmd="openstack-config --set $2 DEFAULTS"
local has_new_cmd="openstack-config --has $1 DEFAULTS"
cmd="$get_new_cmd cassandra_server_list"
val=$($cmd)
$set_cmd new_cassandra_address_list "$val"
cmd="$get_new_cmd zk_server_ip"
val=$($cmd)
$set_cmd new_zookeeper_address_list "$val"
cmd="$has_new_cmd rabbit_user"
val=$($cmd)
if [ $val == 1 ]
then
cmd="$get_new_cmd rabbit_user"
val=$($cmd)
$set_cmd new_rabbit_user "$val"
fi
cmd="$has_new_cmd rabbit_password"
val=$($cmd)
if [ $val == 1 ]
then
cmd="$get_new_cmd rabbit_password"
val=$($cmd)
$set_cmd new_rabbit_password "$val"
fi
cmd="$has_new_cmd rabbit_vhost"
val=$($cmd)
if [ $val == 1 ]
then
cmd="$get_new_cmd rabbit_vhost"
val=$($cmd)
$set_cmd new_rabbit_vhost "$val"
fi
cmd="$has_new_cmd rabbit_ha_mode"
val=$($cmd)
if [ $val == 1 ]
then
cmd="$get_new_cmd rabbit_ha_mode"
val=$($cmd)
$set_cmd new_rabbit_ha_mode "$val"
fi
cmd="$has_new_cmd rabbit_port"
val=$($cmd)
if [ $val == 1 ]
then
cmd="$get_new_cmd rabbit_port"
val=$($cmd)
$set_cmd new_rabbit_port "$val"
fi
cmd="$has_new_cmd rabbit_server"
val=$($cmd)
if [ $val == 1 ]
then
cmd="$get_new_cmd rabbit_server"
val=$($cmd)
$set_cmd new_rabbit_address_list "$val"
fi
cmd="$has_new_cmd cluster_id"
val=$($cmd)
if [ $val == 1 ]
then
cmd="$get_new_cmd cluster_id"
val=$($cmd)
$set_cmd ndb_prefix "$val"
fi
}